UFH · Wet & electric mats · Low-tog underlay

Flooring over underfloor heating in New Eltham

From £38/m² fitted supplied & fitted

Most New Eltham UFH complaints come from the flooring, not the boiler. A 12mm plank with 3mm foam is doing the wrong job. We use 4–5mm LVT or 8mm UFH-rated laminate over ≤1.0 tog underlay so heat reaches 1930s bay-fronted semis with a scattering of post-war infill feet — not the subfloor.

5-star rated locally·10 minutes from our base·From £38/m² fitted
Close-up of fitted lvt in New Eltham
Flooring Over Underfloor Heating · New Eltham

What flooring over underfloor heating in New Eltham actually involves

Most New Eltham UFH complaints come from the flooring, not the boiler. A 12mm plank with 3mm foam is doing the wrong job. We use 4–5mm LVT or 8mm UFH-rated laminate over ≤1.0 tog underlay so heat reaches 1930s bay-fronted semis with a scattering of post-war infill feet — not the subfloor.

Original pine boards over joists — same story as neighbouring Sidcup, so ply overlay before LVT is the norm.

Before we quote a lvt job in New Eltham

  • New Eltham subfloor reality

    Original pine boards over joists — same story as neighbouring Sidcup, so ply overlay before LVT is the norm.

  • Pattern direction

    Plank run follows the longest sightline; in narrow New Eltham hallways that means front-door to kitchen.

  • Door undercut

    We trim doors on the day so they swing cleanly over glue-down LVT — no scraping, no callbacks.

Included with every New Eltham job
  • Only UFH-rated LVT, laminate and engineered wood used
  • Underlay kept below 1.0 tog so heat actually reaches the room
  • Perimeter expansion gap sized for full UFH cycle
  • Manifold and probes protected during fit
Summary

In short — New Eltham UFH flooring from £38/m² fitted, using UFH-rated planks and low-tog underlay so the heat actually reaches the room.

Recent work · New Eltham

"Kitchen extension in Avery Hill, wet UFH under 4mm LVT — floor genuinely warm within a day." — New Eltham customer

New Eltham context

Postcodes: SE9 · Routes: the A20 · Common build: 1930s bay-fronted semis.

Covering Avery Hill, Southwood, Green Lane.

Recent work · near New Eltham

Flooring Over Underfloor Heating jobs we've finished nearby

Flooring Over Underfloor Heating fitted in New Eltham — Herringbone LVT mid-install in a kitchen
Herringbone LVT mid-install in a kitchen — New Eltham, SE9
Flooring Over Underfloor Heating fitted in New Eltham — Herringbone LVT kitchen in evening light
Herringbone LVT kitchen in evening light — New Eltham, SE9
Flooring Over Underfloor Heating fitted in New Eltham — Herringbone LVT through a bay-window reception
Herringbone LVT through a bay-window reception — New Eltham, SE9
New Eltham FAQs

Flooring Over Underfloor Heating in New Eltham — common questions

Do I need to turn UFH off before you fit?

Yes — dropped to 15–18°C for 48 hours before, off during the fit, then ramped back up 2°C per day. We give you the schedule in writing after the New Eltham survey.

What's the max floor surface temperature?

55°C at the plank, 27°C at the floor surface — the industry standard. Above that, planks cup and joints open. We commission with your plumber so we know the ramp-up.

Is LVT better than laminate for UFH?

For heat transfer, yes — 4–5mm LVT sits directly on the screed with a very low thermal resistance. Most new New Eltham kitchens over UFH now go LVT for that reason.

Can I put laminate over UFH in New Eltham?

Yes — but only UFH-rated boards (usually 8mm HDF core, marked on the pack) with an underlay under 1.0 tog. Standard 12mm click laminate will insulate your UFH and cost you heat.

Call WhatsApp Quote